FWP系列 690Vac 14x51mm Class aR 高速熔断器
Product Information
Eaton's Bussmann Division fuses and surge circuit protection ...
- 产品目录
- Logistics Processing
- Why Choose Us
BM & CRO
Best Solution For Your Business.
New - gR operating class with and without striker Eaton’s Bussmann series FWP 14x51 mm class gR fuses provide full range overload and short-circuit protection and are used to protect AC/DC drives and semi conductors. They are available with an optional striker to provide local indication of fuse status or work in the CH14 modular fuse holder to provide remote fuse indication capabililty. aR operating class with and without striker Eaton’s Bussmann series FWP 14x51 mm class aR fuses provide short-circuit protection and are used to protect AC/DC drives and semi conductors. They are available with an optional striker to provide local indication of fuse status or work in the CH14 modular fuse holder to provide remote fuse indication capabililty. Specifications:Eaton’s Bussmann series FWP 14x51 mm class aR fuses provide short-circuit protection and are used to protect AC/DC drives and semi conductors They are available with an optional striker to provide local indication of fuse status or work in the CH14 modular fuse holder to provide remote fuse indication capabililty. Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustrations. Ratings: Volts: 690Vac (IEC) — 700Vac (UL) — 800Vdc (5-50A) Amps: 1-50A IR: 200kA RMS Sym. — 50kA @800Vdc Agency Information: CE, UL Recognition, CSA Component Acceptance for versions without indicator only. Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%. Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. Without Striker Catalog Numbers (Amps) Catalog Numbers Catalog Numbers Catalog Numbers Catalog Numbers FWP-1A14Fa FWP-5A14Fa FWP-20A14Fa FWP-40A14Fa FWP-2A14Fa FWP-6A14Fa FWP-25A14Fa FWP-50A14Fa FWP-3A14Fa FWP-10A14Fa FWP-30A14Fa FWP-4A14Fa FWP-15A14Fa FWP-32A14Fa With Striker Catalog Numbers (Amps) Catalog Numbers Catalog Numbers Catalog Numbers Catalog Numbers FWP-10A14FI FWP-20A14FI FWP-30A14FI FWP-40A14FI FWP-15A14FI FWP-25A14FI FWP-32A14FI FWP-50A14FI • Watts loss provided at rated current. • See accessories on page 216. Fuse type Fuse symbol Rated voltage Rated current (amps) 12t (A2s) Watts loss (w)* Catalog no Pre-arcing Clearing at 600 Vac without striker 14*51mm (9/16*2) 700Vac (UL) 1 0.04 0.41 6.7 FWP-1A14Fa 2 0.08 0.11 8.7 FWP-2A14Fa 3 0.11 0.26 2.8 FWP-3A14Fa 4 0.1 0.23 3 FWP-4A14Fa 600Vac (IEC)700 Vac/dc (UL) 5 2 11 1.6 FWP-5A14Fa 10 4 22 4 FWP-10A14Fa 15 10 70 5.5 FWP-15A14Fa 20 26 180 6.6 FWP-20A14Fa 25 49 320 7 FWP-25A14Fa 30 58 400 9 FWP-30A14Fa 32 68 600 8 FWP-32A14Fa 40 84 750 8 FWP-40A14Fa 50 200 1800 9 FWP-50A14Fa with striker 14*51mm (9/16*2) 700 Vac/600 Vdc (UL) 10 4 32 2 FWP-10A14FI 15 7 63 4 FWP-15A14FI 20 26 234 4 FWP-20A14FI 25 42 378 4 FWP-25A14FI 30 52 468 6 FWP-30A14FI 32 68 600 8 FWP-32A14FI 40 84 750 8 FWP-40A14FI 50 200 1800 9 FWP-50A14FI Carton Quantity Amp Rating Carton Qty 1-60 10 Features and Benefits • Excellent cycling capability and DC performance • Low arc voltage and low energy let-through (I2t) • Low watts loss in a compact size • Used with finger-safe holders/blocksFWP 14x51 mm Class aR fuses