 Fusetron™ FRN-R Class RK5 250Vac/125Vdc 1⁄10-60A, dual element, time-delay fuses

Catalog symbols:

  • FRN-R-_ (non-indicating)

  • FRN-R-_ID (indicating)

Description:

Eaton Bussmann® series advanced protection, energy efficient FRN-R Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings. Time-delay-10 seconds (minimum) at 500% of rated current (8 seconds for 1⁄10-30A sizes).

 

Specifications:

Ratings:

Volts:

  • 250Vac

  • 125Vdc

Amps:1/10-60A

Interrupting rating:

  • 200kA Vac RMS Sym.

  • 20kA Vdc

Agency information

  • UL Listed, Std. 248-12, Class RK-5, Guide JDDZ, File E4273

  • CSA Certified, C22.2 No. 248.12, Class 1422- 02, File 53787

  • CE

Catalog numbers (amps) - non-indictaing fuses

Catalog Numbers

Catalog Numbers

Catalog Numbers

Catalog Numbers

FRN-R-1/10

FRN-R-1-1/4

FRN-R-4

FRN-R-15

FRN-R-1/8

FRN-R-1-4/10

FRN-R-4-1/2

FRN-R-17-1/2

FRN-R-15/100

FRN-R-1-1/2

FRN-R-5

FRN-R-20

FRN-R-2/10

FRN-R-1-6/10

FRN-R-5-6/10

FRN-R-25

FRN-R-1/4

FRN-R-1-8/10

FRN-R-6

FRN-R-30

FRN-R-3/10

FRN-R-2

FRN-R-6-1/4

FRN-R-35

FRN-R-4/10

FRN-R-2-1/4

FRN-R-7

FRN-R-40

FRN-R-1/2

FRN-R-2-1/2

FRN-R-7-1/2

FRN-R-45

FRN-R-6/10

FRN-R-2-8/10

FRN-R-8

FRN-R-50

FRN-R-8/10

FRN-R-3

FRN-R-9

FRN-R-60

FRN-R-1

FRN-R-3-2/10

FRN-R-10

 

FRN-R-1-1/8

FRN-R-3-1/2

FRN-R-12

 

* Open fuse indication available by inserting the sufix “ID." E.g., FRN-R-15ID.

Carton Quantity:

Amp Rating

Carton Qty.

1/10 - 60

10

Features:

  • Provides motor overload, ground fault and short-circuit protection

  • Helps protect motors against burnout from overloads

  • Helps protect motors against burnout from single-phasing on three-phase systems

  • Simplifies and improves blackout prevention (selective coordination)

  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance

            short-circuit and overload protection

  • The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater

            than the ampere rating of the fuse for a minimum of ten seconds

Recommended fuse blocks:

Fuse amps

1-Pole

2-Pole

3-Pole

up to 30

RM25030-1_

RM25030-2_

RM25030-3_

35 to 60'

RM25060-1CR

RM25060-2CR

RM25060-3CR

For additional information see data sheet no. 10289.

Fuse reducers for Class R fuses

Fuse size

Amp size of fuse block or disconnect switch

Catalog no.

(pairs)

Up to 30A

60A

NO.263-R

Up to 30A

100A

NO.213-R

35 to 60A

NO.216-R

35 to 60A

200A

NO.226-R

For additional information on Class R fuse reducers, see data sheet no 1118.

 

 

Fusetron™ FRN-R Class RK5 250Vac, 125/250Vdc 70-600A, dual element, time-delay fuses

Catalog symbols:FRN-R-_

Description:

Eaton Bussmann® series advanced protection, energy efficient FRN-R Class RK5 dual element, current-limiting, time-delay fuses. Time-delay - 10 seconds (minimum) at 500% of rated current.

 

Specifications:

Ratings:

Volts:

  • 250Vac

  • 125Vdc (110-200A)

  • 250Vdc (225-600A)

Amps:70-600A

Interrupting rating

  • 200kA Vac RMS Sym.

  • 20kA Vdc

Agency information

  • UL Listed, Std. 248-12, Class RK5, Guide JDDZ, File E4273

  • CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787

  • CE

Catalog numbers (amps):

Catalog Numbers

Catalog Numbers

Catalog Numbers

Catalog Numbers

FRN-R-70

FRN-R-100

FRN-R-200

FRN-R-400

FRN-R-75

FRN-R-110

FRN-R-225

FRN-R-450

FRN-R-80

FRN-R-125

FRN-R-250

FRN-R-500

FRN-R-85

FRN-R-150

FRN-R-300

FRN-R-600

FRN-R-90

FRN-R-175

FRN-R-350

 

Carton Quantity:

Amp Rating

Carton Qty.

70-100

5

110-600

1

Features:

  • Provides motor overload, ground fault and short-circuit protection

  • Helps protect motors against burnout from overloads and single-phasing when sized properly

  • Simplifies and improves blackout prevention (selective coordination)

  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance

            short-circuit and overload protection

  • The overload element provides protection against low level overcurrent of overloads and will hold on inrush current which is five times

            greater than the amp rating of the fuse for a minimum of ten seconds

Recommended fuse blocks:

Fuse amps

1-Pole

2-Pole

3-Pole

70-100

RM25100-1CR

RM25100-2CR

RM25100-3CR

110-200

RM25200-1CR

RM25200-2CR

RM25200-3CR

225-400

RM25400-1CR

RM25400-2CR

RM25400-3CR

450-600

RM25600-1CR

RM25600-2CR

RM25600-3CR

For additional information on the RM 250 volt fuse blocks, see product brochure no. 3192

use reducers for Class R fuses

Fuse size

Amp size of fuse block or disconnect switch

Catalog no.

(pairs)

65-100A

400A

NO.2641-R

110-200A

NO.242-R

65-100A

600A

NO.2664-R

110-200A

NO.2662-R

225-400A

NO.2664-R

* These reducers are not CSA Certified.

†Single reducer only (pair not required)

For additional information on Class R fuse reducers, see data sheet no 1118.

Current-limiting effects:

Prospective S.C.C.

Let-through current

(apparent RMS symmetrical vs. fuse rating)

-

100A

200A

400A

600A

5000

3000

5000

5000

5000

10000

4000

7000

10000

10000

15000

5000

8000

11000

15000

20000

5000

8000

12000

16000

25000

5000

9000

13000

17000

30000

6000

10000

14000

18000

35000

6000

10000

15000

19000

40000

7000

11000

15000

20000

50000

7000

11000

17000

21000

60000

8000

12000

18000

22000

70000

8000

13000

19000

23000

80000

8000

13000

19000

24000

90000

9000

14000

21000

25000

100000

9000

14000

21000

26000

150000

10000

16000

24000

29000

200000

11000

18000

26000

32000

 

PRE - ORDER NOW
series: FRN-R series, double indication delay slow RK5 fuse
Voltage:
-250Vac (or less)
-125Vdc (1 ⁄ 10-60A, 110-200A)
-250Vdc (225-600A)
Current: 1 ⁄ 10-600A
Segment capacity: 200kA RMS Sym.
Certifications: CE, Std. 248-12, Class RK5,UL Listed, Guide JDDZ, File E4273, CSA Certified, Class1422-01, File 53787.