Einfacher Kauf

Bonjour Invité! Sign up to our mailing list.

086 159 6228 5577

Open 24 hours - 7 days

Please reply us if you are interested so we can send you our complete quotation which includes prices, moq, packaging, delivery time, payment terms etc. please leave a message or send an email.

 

Technical Disclaimer:
The catalog number(s) suggested in the Bussmann series Fuse Selector represents the closest Bussmann series fuse(s) based upon the entered selected search attributes. It is the responsibility of the user to review the product specifications to determine suitability for the intended application.

Eaton Bussmann

GMF and GRF(fuse) HLR (fuse holder) Non-rejecting, time-delay fuse and in-line fuse holders

Catalog symbol: GMF, GRF (fuse) HLR (fuse holder)

Ampere Rating: GMF 3/10 - 6 1/4 A, GRF 7 - 10 A

Voltage Rating: 300 Volts AC or less

Interrupting Rating: 10,000 A

Agency information Fuse

• UL® Listed, Std. 248-14, Guide JDYX, File E19180

• CSA® Certified, C22.2 No. 248.14, Class 1422-01, File 53787

• CE

Fuse holder HLR

• UL Recognized, 12A, 300 Vac, Guide IZLT2, File E14853

• CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235

• CE

HLR-2 and HRL-2L

• UL Recognized, 15A, 300 Vac, Guide IZLT2, File E14853

• CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235

• CE

Catalog Numbers (Amps) and Non-Rejection Holders

Fuse

Holder

Fuse

Holder

GMF-3/10

HLR

GMF-3

HLR

GMF-1/2

HLR

GMF-3-2/10

HLR

GMF-6/10

HLR

GMF-4

HLR

GMF-8/10

HLR

GMF-5

HLR

GMF-1

HLR

GMF-6-1/4

HLR

GMF-1-1/4

HLR

GRF-7

HLR

GMF-1-6/10

HLR

GRF-8

HLR

GMF-2

HLR

GRF-10

HLR

GMF-2-8/10

HLR

GMF-10

HLR

GMF-2-1/2

HLR

Product features

• HLR carrier comes with 6” of #18 red insulated solid copper wire attached to the line side

• Customer inserts a #18 insulated solid copper wire into load side receptacle • Order part number HLR-2 to obtain 6” of #18 black insulated solid copper wire pre-installed in a load side receptacle

• Order part number HLR-2L to obtain 6” of #18 black insulated solid copper wire packaged loose (un-installed)

• An alternative to the HLR fuseholder is the fuseholder. The A fuseholder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235

• Fuse and knob are an integral one-piece unit. There are no replacement knobs (caps) • Units can be panel mounted with a separate steel clip. For the knockout hole (see above), choose #BK/A-104. For the keyhole punch type hole, choose #6374 for panels 0.043” to 0.062” thick, or #4909 for panels 0.030” to 0.042” thick

• Do not put tension on line (rear) terminal of fuseholder

PRE - ORDER NOW
Manufacturer Part Number: GRF-*
Series: GRF series, inline fuse
Current: 8-10A
Voltage: 300Vac (or less)
Breaking capacity: 10kA RMS Sym.
Certification:-CE, Std. 248-14, 0-10A
-UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787.

Request For Quote

Please fill in all required fields and click "Submit", we will contact you via email within 24 hours.

 

If you have any questions, please leave a message or send an emailjhon@cooper-bussman.com.cnWe will reply to you as soon as possible.

Code

GRF Series, Inline Fuse