BRAND :  COOPER BUSSMANN(EATON‘S) 

欧标方体DIN 43 653 690V 10-400A

Product Information

Eaton's Bussmann Division fuses and surge circuit protection ...

  • 产品目录
  • Logistics Processing
  • Why Choose Us

emmet  BM & CRO

          Best Solution For Your Business.  


170M — size 000 and 00, DIN 43653 690 Vac (IEC), 700 Vac/dc (UL), 10 to 400 A


Description

Square body DIN 43653 bolted tags high speed fuses, for the protection of DC common bus, DC drives, power converters/rectifiers and reduced rated voltage starters. Available with and without visual indicator, and Type T indicator for a microswitch.

 

Specifications

Ratings

• Volts:

• 690 Vac (IEC, size 000 and 00)

• 700 Vac (UL, size 000; size 00 100-400 A only)

• 700 Vdc (UL, size 000)

• Amps: 10-400 A

• Interrupting rating:

• 200 kA RMS Sym.

• 50 kA at 700 Vdc (size 000 only)

 

Operating class

• gR - size 000 (10-63 A), size 00 (25-80 A)

• aR - size 000 (>63 A), size 00 (>80 A)

 

Agency Information

• Designed and tested to IEC 60269 Part 4

• UL Recognized, E125085, JFHR2

• CSA Class 53787, File 1422-30 on size 000

• CCC approved

• CE

 

Dimensions — mm The dotted line illustrates the Type T indicator fuse. * Indicatior for size 00 fuses is a red pin.

 

Total Clearing I2t

The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).

 

Arc Voltage

This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.


Power Losses

Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.


Catalog Numbers

Catalog Numbers

Electrical Characteristics

-U/80

*/80 Visual Indicator

-TN/80 Type T

00B/60 Visual

00BTN/60 Type T

Size

Amp

  170M1308

  170M1358

  170M1408



000

10

  170M1309

  170M1359

  170M1409



16

  170M1310

  170M1360

  170M1410



20

  170M1311

  170M1361

  170M1411



25

  170M1312

  170M1362

  170M1412



32

  170M1313

  170M1363

  170M1413



40

  170M1314

  170M1364

  170M1414



50

  170M1315

  170M1365

  170M1415



63

  170M1316

  170M1366

  170M1416



80

  170M1317

  170M1367

  170M1417



100

  170M1318

  170M1368

  170M1418



125

  170M1319

  170M1369

  170M1419



160

  170M1320

  170M1370

  170M1420



200

  170M1321

  170M1371

  170M1421



250

  170M1322

  170M1372

  170M1422



315


  170M2608

  170M2658

  170M2708

  170M2758

00

25


  170M2609

  170M2659

  170M2709

  170M2759

32


  170M2610

  170M2660

  170M2710

  170M2760

40


  170M2611

  170M2661

  170M2711

  170M2761

50


  170M2612

  170M2662

  170M2712

  170M2762

63


  170M2613

  170M2663

  170M2713

  170M2763

80


  170M2614

  170M2664

  170M2714

  170M2764

100


  170M2615

  170M2665

  170M2715

  170M2765

125


  170M2616

  170M2666

  170M2716

  170M2766

160


  170M2617

  170M2667

  170M2717

  170M2767

200


  170M2618

  170M2668

  170M2718

  170M2768

250


  170M2619

  170M2669

  170M2719

  170M2769

315


  170M2620

  170M2670

  170M2720

  170M2770

350


  170M2621

  170M2671

  170M2721

  170M2771

400

• Watts loss provided at rated current.

• Microswitch indicator ordered separately.

• See accessories on pages 185-186.

• For fuse curves see page 119.

 

Features and Benefits

• Excellent DC performance

• Low arc voltage and low energy let-through (I2t)

• Low watts loss

• Superior cycling capability

 

Typical Applications

• DC common bus

• DC drives

• Power converters/rectifiers

• Reduced voltage starters