Einfacher Kauf

086 159 6228 5577

FWP 系列 (22*58MM)

 

 

Ferrule — FWP 22 x 58mm 690V/700V (IEC/UL): 20-100A, Striker Optional

 

 

New - gR operating class with and without striker

Eaton’s Bussmann series FWP 14x51 mm class gR fuses provide full range overload and short-circuit protection and are used to protect AC/DC drives and semi conductors.

They are available with an optional striker to provide local indication of fuse status or work in the CH22 modular fuse holder to provide remote fuse indication capabililty.

 

aR operating class with and without striker

Eaton’s Bussmann series FWP 22x58 mm class aR fuses provide short-circuit protection and are used to protect AC/DC drives and semi conductors.

They are available with an optional striker to provide local indication of fuse status or work in the CH22 modular fuse holder to provide remote fuse indication capabililty.

 

 

Description:
Ferrule style high speed fuses. with and without indicating striker.

 

Ratings:
Volts: 690Vac (IEC); 700Vac (UL)
Amps: 20-100A
IR: 200kA RMS Sym. 50kA @ 500Vdc

 

Agency Information: CE, UL Recognition

 

 

Features and Benefits
• Excellent cycling capability and dc performance
• Low arc voltage and low energy let-through (I2t)
• Low watts loss in a compact size
• Used with finger-safe holders/blocks

 

Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters

 

Catalog Numbers

Fuse type

Fuse symbol

Rated voltage

Rated current (amps)

12t (A2s)

Watts loss (w)*

Catalog no

Pre-arcing

Clearing at 600 Vac

without striker

22*58mm (7/8*2-9/32)

700 Vac/dc (UL)

20

23

390

5

FWP-20A22F

25

37

630

6

FWP-25A22F

32

55

780

8

FWP-32A22F

40

88

960

12

FWP-40A22F

50

155

2200

12.5

FWP-50A22F

63

280

4000

15

FWP-63A22F

80

550

7800

15

FWP-80A22F

100

1100

15600

16.5

FWP-100A22F

with striker

22*58mm (7/8*2-9/32)

700 Vac/dc (UL)

20

19

260

6

FWP-20A22FI

25

34

410

6

FWP-25A22FI

32

53.5

605

8

FWP-32A22FI

40

68

760

9

FWP-40A22FI

50

135

1600

9.5

FWP-50A22FI

63

280

3080

11

FWP-63A22FI

80

600

6600

13.5

FWP-80A22FI

100

1100

12500

16

FWP-100A22FI

 

Without Striker Catalog Numbers (Amps)

 

Catalog Numbers

Catalog Numbers

Catalog Numbers

Catalog Numbers

FWP-20A22F

FWP-32A22F

FWP-50A22F

FWP-80A22F

FWP-25A22F

FWP-40A22F

FWP-63A22F

FWP-100A22F

 

With Striker Catalog Numbers (Amps)

Catalog Numbers

Catalog Numbers

Catalog Numbers

Catalog Numbers

FWP-20A22FI

FWP-32A22FI

FWP-50A22FI

FWP-80A22FI

FWP-25A22FI

FWP-40A22FI

FWP-63A22FI

FWP-100A22FI

 

Electrical Characteristics

Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).

 

Arc Voltage

This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.

 

 Power Losses

Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.

 

 

Carton Quantity

Amp Rating

Carton Qty

20-100

10

*IEC/UL Voltage rating 690/700

 

Product Information

Open Eaton's Bussmann Division fuses and surge circuit protection ...